top of page
DTX Carbon Detection Tape Logo 1.png

See the leak.

DTX Tape continuously monitors leak-prone joints and changes from purple to yellow when CO₂ escapes—so engineers spend less time searching for leaks and more time fixing the problem.

DTX Tape Solo.png

THE PROBLEM WITH SPOT CHECKS

Your handheld leak detector only works
while you’re using it.

Small or intermittent CO₂ leaks can be difficult to find. Engineers have told us that locating the source of a leak within a system can take hours, days or sometimes even weeks—checking connections one at a time, often with no clear indication of where to start.

What if the system could show you where the leak happened?

A CONTINUOUS VISUAL INDICATOR

Let                          show you where the leak is.

DTX_Tape_Purple_Transparent_001 (1).png

Apply the tape to leak-prone joints and leave it in place. When CO₂ leaks, it changes from purple to yellow at the source—so when there’s a problem, you’re not starting the search from scratch.

EASY TO APPLY

DTX Tape can be left in place for at least one year*, providing continuous visual indication between inspections. It changes colour within five minutes of contact with CO₂ and, because the response is reversible, returns to purple within one hour of the leak being fixed.

PERFORMANCE AT A GLANCE

Even the smallest leaks produce a visible colour change response. 

0.5 oz/year

Detects leaks as small as 0.5 oz/year—approximately equivalent to one bubble per minute during a typical soap-and-water test.

Within 5 min

Changes from purple to yellow within five minutes when a leak is detected

Within 1 hour

Returns to purple within one hour of the leak being fixed.

At least 1 year*

Can remain applied for continuous visual monitoring between inspections.

WHY                    ?

DTX_Tape_Purple_Transparent_001 (1).png

An engineer’s time is too valuable to spend searching for leaks.

DTX Tape turns leak searching into a simple visual inspection

—helping engineers move more quickly from finding the problem to fixing it.

Less time searching. More time fixing.

Keep a visual marker  at the connections most likely to leak.

Monitor multiple joints at once.

Apply the tape to leak-prone connections throughout the system and inspect them visually without testing every joint individually.

See where to start.

A yellow colour change draws attention to the joints that needs investigating.

Support faster maintenance.

The visible response helps you locate and check connections during routine maintenance and commissioning.

PROVEN IN THE FIELD

Real-world results. 

APPLICATIONS

Built for systems where CO₂ leaks are difficult to find.

Apply DTX Tape to leak-prone joints throughout a CO₂ system to create clear visual checkpoints for routine inspections, troubleshooting and commissioning.

refrigeration-and-cold-storage.png

Refrigeration and cold storage

hvac-systems.png

HVAC systems

food-production.png

Food production

breweries-and-beverage-dispense.png

Breweries and beverage dispense

food-production.png

Laboratories

image.png

Made to stay for at least a year.

When correctly applied and used under the recommended conditions, DTX Tape is guaranteed to remain in place for at least 12 months.


12  months
guaranteed

It may last longer, but why do we only guarantee one year? Because 12 months is how long we’re comfortable guaranteeing that the tape will stay securely in place. After that, the adhesive may gradually lose some of its tack, while dirt, moisture, temperature and general wear and tear can all affect how well it remains attached. Does that mean it suddenly stops working after 365 days? No. Under the right conditions, you may get considerably longer from it. We simply don’t think it’s fair to promise something we can’t confidently guarantee.

FREQUENTLY ASKED QUESTIONS

The details, without the guesswork.

TEMPERATURE AND ENVIRONMENTAL CONDITIONS

At what temperatures can DTX Tape be left in place on gas pipes? DTX Tape is suitable for continuous use on pipes and fittings at temperatures up to 50°C.

Can I use DTX Tape on hotter pipes? Yes, but only for a short-term leak spot checks. Prolonged exposure to temperatures above 50°C can affect the tape’s chemistry, causing permanent yellowing even when no CO₂ leak is present. This may create a false-positive indication, so DTX Tape should not be left in place for continuous monitoring above 50°C.

Can DTX Tape be used outdoors? Yes—for shorter-term leak checks, with more frequent inspection and replacement. UV exposure and heat can fade the tape’s colour and reduce how long it stays securely attached to pipes. In direct sunlight, you’ll need to apply fresh tape more frequently. It may remain suitable for days or even weeks, depending on UV exposure and conditions, rather than lasting a full year. Check it regularly and replace it if the colour fades or the tape begins to lift. For longer-term use, DTX Tape is recommended for indoor applications, where our 12-month guarantee applies when installed and used as directed.

What other conditions can affect its response? Dust, rust and other particles may slow the colour change. The tape should still respond to CO₂ if it becomes wet, although environmental and operating conditions can affect overall performance. Do not apply it to freshly painted pipes, as this may cause permanent yellowing or detection failure.

AFTER APPLICATION

What happens after the leak is fixed? The colour response is reversible. Once the CO₂ flow has stopped, the tape should return from yellow to purple within one hour.

Can removed tape be reapplied? Yes, DTX Tape can be reapplied. However, we recommend using a fresh length for the best adhesion and performance. Removed tape may have picked up dust or other foreign particles and lost some of its tack, affecting how securely it bonds when reapplied.

How should a repair be confirmed? Remove the tape before confirming the repair using the appropriate leak-testing procedure, as DTX Tape may reduce or redirect the flow of escaping gas. Once the repair is confirmed, we recommend applying a fresh length of tape if continued monitoring is required.

SAFETY AND PRODUCT LIMITATIONS 

Does DTX Tape replace a CO₂ alarm? No. DTX Tape is a supplementary, localised visual indicator. It is not a CO₂ alarm, personal-safety monitor or life-safety device and must not replace required gas-detection equipment, ventilation or safety systems.

Does DTX Tape prevent or repair leaks? No. DTX Tape is a visual indicator that changes colour to indicate that CO₂ may be leaking from the joint where it is applied. The tape itself does not prevent, contain or repair a leak.

Can it detect gases other than CO₂? No. DTX Tape is intended only for carbon dioxide. Exposure to NOx or SOx gases may cause permanent yellowing.

Reach out to us to find your local distributor →

Looking for                           ?                        

DTX Carbon Detection Tape Logo white_edi

Click to Buy

Amazon logo to link tree

Just a heads-up: you’ll always get the best price when you buy directly from us or one of our partner distributors.

bottom of page